Topic : Problem with Cortex_pgm.exe

Forum : ARM

Original Post
Post Information Post
March 3, 2009 - 3:48pm
Guest

Hi

I have set up 3 computers for production programming STM32F101C6T6. With the first batch of processors everything went well but, now we have moved to the next batch, every device fails to program. This seems to be a machine-specific issue as the machine which I use for development works fine with both batches. I have eliminated the Rlink and associated leads by substitution. All of the machines are running the same software versions.

The unprogrammable device markings are:-

STM32F101C6T6A
GHAAU 93
CHN841

While the working batch are marked:-

STM32F101C6T6
991B8 93
MYS 745

If you can help me solve this problem I would be very grateful.

Best regards

Damon

Replies
Post Information Post
+1
0
-1
March 3, 2009 - 4:26pm
Raisonance Support Team

Hi,

I will need to know which versions of Windows (and service packs) you are running on your different PCs, and also the version(s) of Ride you are using. (kit Ride and RKit-ARM)

Please make sure that you really have the same version of Ride on all PCs, and that you haven't installed some patches on some and not others. (try to copy the files in \bin and \sim\ARM from the working PC to the others) There are differences between the two batches you referenced, and I'm surprised that it works at all with an old unpatched software with the new batch of devices. In any case I recommend to install the latest version of the software on all PCs.

I hope it helps.

Best Regards,

Vincent