Hiya C:\Program Files\Raisonance\Ride\Bin>str9_pgm.exe U STR9_pgm: command-line programming tool for STR9 Opening com with RLink...OK. Getting Serial Number and Firmware version...OK. Closing COM...OK. C:\Program Files\Raisonance\Ride\Bin>str9_pgm.exe U STR9_pgm: command-line programming tool for STR9 Opening com with RLink... C:\Program Files\Raisonance\Ride\Bin>str9_pgm.exe U STR9_pgm: command-line programming tool for STR9 Opening com with RLink... C:\Program Files\Raisonance\Ride\Bin>str9_pgm.exe U STR9_pgm: command-line programming tool for STR9 Opening com with RLink...OK. Getting Serial Number and Firmware version...OK. Closing COM...OK. C:\Program Files\Raisonance\Ride\Bin>str9_pgm.exe U STR9_pgm: command-line programming tool for STR9 Opening com with RLink...OK. Getting Serial Number and Firmware version...OK. Closing COM...OK. C:\Program Files\Raisonance\Ride\Bin>str9_pgm.exe U STR9_pgm: command-line programming tool for STR9 Opening com with RLink... C:\Program Files\Raisonance\Ride\Bin>str9_pgm.exe U STR9_pgm: command-line programming tool for STR9 Opening com with RLink... C:\Program Files\Raisonance\Ride\Bin> It seems that the STR9_pgm.exe does not exit in its entirety even though it returns me to the prompt? Kind regards |
Hi,
I tried the test you describe and saw no problem.
Please give us more information...
Which version of Windows (and service packs) are you using?
Which versions of the Ride7 and RKit-ARM are you using?
Do you connect the RLink through a USB hub or directly on the PC?
How many other USB devices are connected on this PC?
Best Regards,
Vincent
Windows XP Professional Version 2002 Service Pack 3
The RLink is directly connected.
Ride version 7.16
Rkit-ARM 1.16.0930
4 other things connected via USB.
Mouse, USB-DAQ, Keyboard and the unit I am programming - I need to communicate with it after programming.
Hi
Can you try with latest RIde7 and RKit-ARM from
http://www.mcu-raisonance.com/mcu_downloads.html
If this does not solve your issue and we have to give you a fix
it will be done assuming you are working with that version.
Can you also test the same hardware (RLink + Target board) on another PC
just for testing.
Regards,
Matloub
Hi,
Please also try if disconnecting the STR9's USB and the USB-DAQ makes a difference.
(just for understanding the problem)
Best Regards,
Vincent
Thanks again guys...
Upgrading to the newest version of the software seems to have solved the issue.
Kind Regards
BDM