Topic : RLINK-STX cannot program ST72324J6

Forum : ST7/STM8

Original Post
Post Information Post
February 20, 2008 - 11:17am
Guest

I have RLINK-STX and I have problem when programming, reading flash and verify ST72324J6. I always get the message like this: "Unable to install the ICP driver in RAM. Please check device selection, power and connections." . But for reading and writing options byte, erase and blank check, I have no problem. Is anyone can help me to solve this problem ?

Replies
Post Information Post
+1
0
-1
February 20, 2008 - 2:00pm
Raisonance Support Team

Hi,

We will need more information for understanding your problem. Please fill this form and send the answers to 'support@raisonance.com':
http://www.raisonance.com/Forum/punbb/viewtopic.php?id=2231

Best Regards,

Vincent

+1
0
-1
October 22, 2008 - 5:17pm
Guest

Hello markus1268

I have RLINK-STX and I have problem same when programming, reading flash and verify ST72321J9.

I always get the message like this: "Unable to install the ICP driver in RAM. Please check device selection, power and connections." .

Reading and writing options byte, erase and blank check are ok
How can you solve this problem?

+1
0
-1
October 22, 2008 - 5:29pm
Raisonance Support Team

Well, if you ask the same question, you should expect the same answer... ;)

Please fill this form and send the answers to 'support@raisonance.com':
http://www.raisonance.com/Forum/punbb/viewtopic.php?id=2231

Best Regards,

Vincent